700W Pure Sine Wave Inverter

  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Beijing

  • Validity to:

    Long-term effective

  • Last update:

    2020-07-03 23:08

  • Browse the number:

    488

Send an inquiries

Company Profile

Ruian Enchi Electronic Technology Co., Ltd

By certification [File Integrity]

Contact:raenchi(Mr.)  

Email:

Telephone:

Phone:

Area:Beijing

Address:Beijing

Website:http://www.raenchidz.com/ http://raenchi.gpncctv.com/

Product details

Over Input Voltage Alarm and Shut Off (OUP)

When the 12 volt DC power supply voltage exceeds 15.0V~15.5VDC (or 30--31V DC), steady beep can be heard, and the red LED light will be on, for 8900 series, if those models is more than 1000W, you will see OUP in the display panel, the inverter will automatically shut down.


Low Input Voltage Alarm

When the 12 (24) voltage DC power supply voltage drops below 10.2V-10.8volts (or 20.4—21.6V DC), red LED is on.


Low Input Voltage Shut Off (LUP)

When the 12 (24) volt DC power supply voltage drops below 9.2V-9.8 (or 18.4—19.6V DC), volts, the inverter will automatically shut down, red LED is on, for 8900 series, if those models is more than 1000W, you will see LUP in the display panel , and you still can hear the beep until the voltage is lower than 8.5+/-0.5V (or 17--18V DC),.

If input voltage back to normal, it can automatically resume working.


Overheating Alarm and Shut off (OCP)

When the internal temperature exceeds the regulated temperature due to the increase of surrounding air temperature, the inverter will automatically shut down, red LED is on and alarming is heard. For 8900 series, if those models is more than 1000W, you will see OCP in the display panel.

When the internal temperature drops below the surrounding air temperature, the inverter will automatically return to normal operation.


Over Load Alarm and Shut Off (OLP)

When the starting power exceeds the rated power much, the inverter will automatically shut down, Red LED is on and alarming is heard. For 8900 series, if those models is more than 1000W, you will see OLP in the display panel.

When being in over current protection state, the inverter can’t automatically restore normal operation, but return to normal operation by switching off and reset.

You should await one minute to restart the inverter.


Short Circuit Protection (OPP)

This inverter has short circuit protection function to protect the internal circuitry, if the load internal part or outer cable has short circuit condition, and over 20 seconds, it will be locked automatically, if you can solve the short circuit within 20 seconds, then still can work. When there is short circuit, For 8800 series, if those models is more than 1000W .yellow LED will be on. For 8900 series, if those models is more than 1000W, you will see OPP in the display panel. if those models is low than 1000W, if the load internal part or outer cable has short circuit condition, and over 3 seconds, it will be locked automatically, every LED is no change. if you can solve the short circuit within 3 seconds, then still can work, every LED is no change.